Cleared Indications for Use
The HeartBeam System is a portable non-invasive recorder intended to record, store, and transfer a patient’s 3-Lead (in three-directions) electrocardiogram (ECG) acquired from 5 electrodes. The device is intended to be used by adult patients in either a clinical setting or at home. The device does not conduct cardiac analysis and can be used with an ECG Viewer software system for manual interpretation of non-life-threatening arrhythmias by a physician or healthcare professional.
The HeartBeam 12-Lead ECG Synthesis Software synthesizes a 12-Lead ECG from the HeartBeam System 3-Leads (in three-directions) recording device, producing a visual 12-Lead ECG representation that is similar, but not identical, to the same leads of a standard diagnostic 12-Lead ECG. The synthesized 12-Lead ECG output is solely intended for manual assessment of normal sinus rhythm and the following non-life-threatening arrhythmias: sinus arrhythmia, sinus tachycardia, sinus bradycardia, atrial premature complexes, atrial fibrillation, and ventricular premature complex. The synthesized 12-Lead ECG output is not intended for the assessment of any other arrhythmia or conditions (including but not limited to: other atrial arrhythmias, ventricular arrhythmias, hypertrophy, conduction disorders, myocardial infarction or ischemia, pacemaker functions, localization of arrhythmia foci, ECG wave abnormalities, and/or any other disorder). The software does not conduct cardiac analysis and is not intended to replace a standard 12-Lead ECG. The 12-Lead ECG Synthesis Software is intended for adult use only.
For full safety information, see the below.
The HeartBeam 12-Lead ECG Synthesis Software synthesizes a 12-Lead ECG from the HeartBeam System 3-Leads (in three-directions) recording device, producing a visual 12-Lead ECG representation that is similar, but not identical, to the same leads of a standard diagnostic 12-Lead ECG. The synthesized 12-Lead ECG output is solely intended for manual assessment of normal sinus rhythm and the following non-life-threatening arrhythmias: sinus arrhythmia, sinus tachycardia, sinus bradycardia, atrial premature complexes, atrial fibrillation, and ventricular premature complex. The synthesized 12-Lead ECG output is not intended for the assessment of any other arrhythmia or conditions (including but not limited to: other atrial arrhythmias, ventricular arrhythmias, hypertrophy, conduction disorders, myocardial infarction or ischemia, pacemaker functions, localization of arrhythmia foci, ECG wave abnormalities, and/or any other disorder). The software does not conduct cardiac analysis and is not intended to replace a standard 12-Lead ECG. The 12-Lead ECG Synthesis Software is intended for adult use only.
For full safety information, see the below.